Tensile properties of grey cast irons measured on test pieces machined from cast samples

Material Designation Relevant Wall Thickness 0,2% Proof Strength Tensile Strength Elongation
Symbol Number t mm Rp0,2 MPa min Rm MPa min A % Min
EN-GJS-350-22-LTa 5.1300 t ≤ 30 220 350 22
30 < t ≤ 60 210 330 18
60 < t ≤ 200 200 320 15
EN-GJS-350-22-RTb 5.1301 t ≤ 30 220 350 22
30 < t ≤ 60 220 330 18
60 < t ≤ 200 210 320 15
EN-GJS-350-22 5.1302 t ≤ 30 220 350 22
30 < t ≤ 60 220 330 18
60 < t ≤ 200 210 320 15
EN-GJS-400-18-LTa 5.1303 t ≤ 30 240 400 18
30 < t ≤ 60 230 380 15
60 < t ≤ 200 220 360 12
EN-GJS-400-18-RTb 5.1304 t ≤ 30 250 400 18
30 < t ≤ 60 250 390 15
60 < t ≤ 200 240 370 12
EN-GJS-400-18 5.1305 t ≤ 30 250 400 18
30 < t ≤ 60 250 390 15
60 < t ≤ 200 240 370 12
EN-GJS-400-15 5.1306 t ≤ 30 250 400 15
30 < t ≤ 60 250 390 14
60 < t ≤ 200 240 370 11
EN-GJS-450-10 5.1307 t ≤ 30 310 450 10
30 < t ≤ 60 to be agreed upon between the manufacturer
60 < t ≤ 200 and the purchaser
EN-GJS-500-7 5.3200 t ≤ 30 320 500 7
30 < t ≤ 60 300 450 7
60 < t ≤ 200 290 420 5
EN-GJS-600-3 5.3201 t ≤ 30 370 600 3
30 < t ≤ 60 360 600 2
60 < t ≤ 200 340 550 1
EN-GJS-700-2 5.3300 t ≤ 30 420 700 2
30 < t ≤ 60 400 700 2
60 < t ≤ 200 380 650 1
EN-GJS-800-2 5.3301 t ≤ 30 480 800 2
30 < t ≤ 60 to be agreed upon between the manufacturer
60 < t ≤ 200 and the purchaser
EN-GJS-900-2 5.3302 t ≤ 30 600 2
30 < t ≤ 60 to be agreed upon between the manufacturer
60 < t ≤ 200 and the purchaser
NOTE 1 The designation is irrespective of the type of cast sample
NOTE 2 For high damping capacity and thermal conductivity, EN-GJL-100 (5.1100) is the most suitable material.
NOTE 3 The figures given in bold indicate the minimum tensile strength to which the material designation of the grade is related. The values relate to an as-cast sample diameter corresponding to the applicant relevant wall thickness range according to table 3.
NOTE 4 For relevant wall thickness more than 200mm, the manufacturer and the purchaser shall agress on the type and size of cast sample and the minimum values to be obtained.
a If tensile strength is specified as a characterizing property, the type of the sample (see 8.2) should aslo be stated in the order. If not stated in the order, the type of sample is left to the discretion of the manufacturer.
b This value is included as the lower limit of the relevant wall-thickness range.